Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM01496
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/18/2021 | DTRAMME1 | ENGINEERING | REVIEW | Completed | |
| 03/18/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 03/22/2021 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/22/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 03/22/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 03/23/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Plumbing fixtures that receive or discharge liquid waste (e.g. P1 and P2) shall be directly connected to the sanitary drainage system. The use of grey water from other than residences requires a permit from the State of Arizona in addition to the connection to the public sewer. Reference: Section 301.3, IPC 2018. 2. The fixture drain serving an automatic clothes washer shall connect to a fixture branch that is at least 3 inches in diameter. Reference: Section 406.2, IPC 2018. 3. Provide pressure-absorbing devices for the water connections to appliances equipped with quick-acting or solenoid valves (e.g. clothes washer). Reference: Section 604.9, IPC 2018. |
| 03/23/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide heating and cooling load calculations to justify the heating/cooling capacities of the existing and proposed HVAC units. Reference: Section C403.1.1 and C502.2.3, IECC 2018. 2. Clarify the location of the proposed condensing unit. Detail 1/M1.0 notes it as being on the roof and at grade. Reference: Section 107.2.1, IBC 2018. 3. Secure the refrigerant circuit access ports of the proposed condensing unit to prevent unauthorized access. Reference: Section 1101.10, IMC 2018. |
| 03/23/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 03/24/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved |