Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T21CM01487
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/18/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 03/18/2021 | DTRAMME1 | ENGINEERING | REVIEW | Passed | |
| 03/18/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Plans are not clear with the scope of work. 50 w Valencia shows a store. We need a better site plan to show scope of work. Show set backs to existing structures. |
| 03/22/2021 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/22/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 03/22/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please provide electrical plans sealed by a registrant registered in Arizona for the electrical wiring methods. Ref; 2018 IBC 107.2.1 |
| 03/22/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. General: Please provide a more complete site plan, indicating existing streets, buildings, property lines, new structure, dimensions to locate the new structure from property lines and existing structures, etc. 2. General: Please provide specifications, plans, details, and sections for the new cooler box. 3. General: Please provide written responses to all review comments. |
| 03/22/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Show that the walk-in cooler/freezer meets the construction requirements of Section C403.10.2, IECC 2018. 2. Show that the walk-in cooler/freezer meets the efficiency requirements of Section C403.10.2.1, IECC 2018. |
| 03/24/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM01487 50 W Valencia Rd TRANSMITTAL: March 24, 2021 This site is located in the C-1 zone. 1. It appears that a building, cool box, expansion is proposed. As this is a commercial site a development package (DP), commercial site plan, is required to be submitted and approved prior to approval of the building plans. At a minimum the DP must meet the requirements of the Checklist for Minor Development Changes to Existing Commercial/Industrial Sites found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf. The DP is a separate submittal from the building plans and must be submitted at: https://docs.tucsonaz.gov/Forms/tucsonpermitapp. Under “Submission Type*” “Site Review” Until the DP is approved Zoning cannot approve the building plans. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/25/2021 | PCAMARE1 | OUT TO CUSTOMER | Completed |