Permit Number: T21CM01481
Parcel: 134050530

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM01481
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2021 PCAMARE1 ENGINEERING REVIEW Passed
03/09/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM01481
9401 E El Cajon Dr
Attached Carport

TRANSMITTAL: March 9, 2021
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Based on a wall height less than 13’-4” the required front street perimeter yard setback is 20’-0” proposed is 7’-9”.
03/10/2021 ANDREW CONNOR NPPO REVIEW Passed
03/18/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide the size and type of roof sheathing referenced at detail #5/A-3.

Provide the size and type of wall sheathing referenced at detail #6/A-3.