Permit Number: T21CM01291
Parcel: 129051740

Address:
2144 E 17TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM01291
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/31/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Development Services Department Zoning Review

PROJECT:
T21CM01291
2144 E 17th St
Livingroom Addition

TRANSMITTAL: March 31, 2021


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the C-1 zone (UDC 4.7.20). A single-family residence is a permitted use in this zone (Table 4.8-4).

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall, see UDC Article 6.4.5.B and Figure 6.4.5-A.

The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). Proposed side street perimeter yard setback from the proposed addition to the street property line along Plumber Ave. is 7’-0”

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). Based on a wall height of less than 13’-4” the required front street perimeter yard setback from the proposed addition to the street property line along 17th St. is 20’-0”, propose setback is 13’-0”.

DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf.