Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM01172
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/18/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Passed | |
| 03/10/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 03/16/2021 | NMARTEL1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL Nicholas Martell, Planner T21CM01172 7592 E Placita Vista Del Bosque Wall Permit March 16, 2021 The residential wall plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. 1. The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear .) 1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; 2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall. The plans, as provided, do not meet minimum UDC standards. The applicant can apply for a Design Development Option (DDO) to increase the allowable wall height. The information for the DDO can be found here: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf The following is a transmittal for the DDO, should the applicant choose to apply. ZONING REVIEW TRANSMITTAL Description: Wall Height Increase COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. The maximum height of a wall or fence within a perimeter yard shall be six (6) feet (UDC Section 6.6.2.I). The maximum height of a retaining wall is ten (10) feet. The applicant is proposing an increase in wall height from 6' to 7.83' within the perimter yard as measured to the SOUTH property line. A DDO is required. If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |