Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW - RESIDENTIAL
Permit Number - T21CM01141
Review Name: 3RD PARTY REVIEW - RESIDENTIAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/29/2021 | SSHIELD1 | NPPO | REVIEW | Passed | |
04/29/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T20CM01141 878 W Calle De Los Higos Second Story Family Room Addition (1st Review) TRANSMITTAL DATE: March 4, 2021 This site is located in PAD-10. A single-family residence (SFR) is a permitted use in this PAD 1. Zoning has reviewed the residential plan for compliance with PAD-10 but until approved by the Mercado District Design Review Committee Zoning cannot approve the plans. If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov. |
04/29/2021 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
05/03/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T21CM01141 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Clarify the location of the balcony and patio cover in relation to the property, R106.1.1. Structures may not extend beyond the property boundry. FLOOR PLANS: 1. Roof projections extending into the 3-foot fire separation distance require not less than one-hour fire-resistive construction on the underside. Provide notation for compliance with R302.1 (City of Tucson Amended) for the roof overhang (each story). The fire protected overhang may not extend closer than 24” from the property line. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/04/2021 | IMONSHI1 | OUT TO CUSTOMER | Completed |