Permit Number: T21CM01019
Parcel: 114540160

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM01019
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/16/2021 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T21CM01019
Residential Addition
February 16, 2021
The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.

1. The side perimeter yard setback in the RX-1 zone is 20'. Zoning cannot approve the plans as is.

The applicant may apply for a Design Development Option (DDO), which can be used to reduce required setbacks. The application packet can be found at the following web page: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf

If the applicant wishes to apply for the DDO, the following is a transmittal for the zoning administration team:

This site is located in the RX-1 zone (UDC 4.7.6). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3). See Use-Specific Standards 4.9.7.B.6, .8, & .9.

The minimum setback is twenty feet (20) facing each interior property line (Table 6.3-1.A).

The applicant is proposing a reduction in the side perimeter yard setback from 20' to 8', as measured from the NORTH property line.

A DDO is required.

If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
02/16/2021 NMARTEL1 BUILDING-RESIDENTIAL REVIEW Reqs Change The existing 6 x 10 beam is not sized for accepting additional roof loads. Show a larger beam or a support post with footer.
Ken Van Karsen
837-4912
02/23/2021 ANDREW CONNOR NPPO REVIEW Passed
03/31/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change Project: (T21CM01019)
Address: (8930 E BEARS PATH RD)
This project is within a mapped flood hazard area and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page: https://docs.tucsonaz.gov/Forms/tucsonpermitapp.
Instructions:
1. Is this for a new or existing activity application? - Please select New Application.

2. Submission Type - Select Floodplain Use Permit.

3. Project Name - Enter a name for your project.

4. Select Street Name from the list. You can type the first two letters or number to get closer to your choice in the list. Then select the rest of the address in the boxes provided.

5. Type of Permit - Select Commercial or Residential (Residential is for work on single family residences and duplexes.)

6. Complete the Applicant Info. (Note APA# is for applicants with an advance payment account. Leave blank is you do not have an APA account.

7. Complete the Contractor, Owner and Architect/Engineer sections as applicable.

8. Supporting Documentation Upload - Provide a complete cost estimate for the project. You may also provide additional documents you think will be helpful.

9. Sign the application and submit.