Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T21CM00900
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | |
| 04/01/2021 | NMARTEL1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL Nicholas Martell, Planner T21CM00900 Residential Addition April 1, 2021 The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. 1. Please resubmit the plans conforming to the requirements of the residential plot plan found at the following link: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf a. A full site plan with all setbacks, elevation drawings, lot coverage calculations and other plot plan standards is required. B. The minimum perimeter yard setback for a structure in the R-3 zone is 6' or 2/3 the height of the building, whichever is greater. The setbacks provided do not meet current zoning standards. Zoning cannot determine what the required setback will be until we receive an accurate elevation drawing with the correct heights. If the applicant wishes to keep the proposed 5' setbacks, a Design Development Option (DDO) may be applied for. Information about the DDO can be found here: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. Before the DDO can be applied for, please resubmit the plans by referring to the PDF of the residential plot plan copied above. If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |
| 04/08/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits FOUNDATION PLAN: 1. Dimension the footing length, width, and depth into undisturbed soil for each footing type and condition, R403.1.1. The roof loads may not be supported with a slab without a foundation. FRAMING PLAN: 1. Provide a complete roof framing plan with beams sized with appropriate load carrying capacity, R301.1. Two separated 2X rafters may be support the roof loads. 2. Show the beam size located between the existing and proposed patio covers. This beam may require replacement if undersized for the new roof loads. SECTIONS - DETAILS: 1. Show the Post Section Detail with #4 rebar in the footing, R403.1. 2. Notate and specify the size and length of anchor bolts, R403.1. 3. Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
| 04/30/2021 | AWARNER1 | NPPO | REVIEW | Passed |