Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T21CM00882
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/23/2021 | JVINCEN1 | FIRE | REVIEW | Reqs Change | R2 (Apartments) require a fire sprinkler system per '18 IFC 903.2.8. Indicate on cover sheet, fire sprinklers will be installed. |
| 02/23/2021 | PCAMARE1 | ENGINEERING | REVIEW | Reqs Change | PROJECT: T21CM00882 Building Plan Review (1st Review) 441 W Dakota St #01 TRANSMITTAL DATE: February 3, 2021 A development package will be required for this project. If you have any questions about this transmittal, Contact Paul Camarena any time during the week by email Paul.Camarena@Tucsonaz.gov |
| 02/23/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM00882 441 W Dakota St MultiFamily TRANSMITTAL: February 22, 2021 This site is located in the O-3 zone (UDC 4.7.15). Multifamily is an allowed use in the zone (Table 4.8-3). 1. Per Unified Development Code (UDC) Article 11.3.7.A.3. Any residential development consisting of three or more dwelling units on an integrated site or single lot is considered multifamily. Per UDC Article 6.3.3.D multifamily is considered a nonresidential use therefore a Development Package (DP) the meets the requirements of Administrative Manual 2-06 is required to be submitted and approved prior to approval of this building plan set. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
| 03/01/2021 | CTREVIL1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 03/09/2021 | PIMA COUNTY | 2ND PARTY REVIEW | REVIEW | Reqs Change | T21CM00882 RFC 2nd Party Comments 3/8/2021 GENERAL COMMENTS: - Provide the project valuation. - Provide, as a separate document, a Manual J or mechanical load calcs for the apartment unit. - Provide a Code Review Analysis with the following information: Use & Occupancy, Special Detailed requirements based on Occupancy and Use (Ch. 4), Building Heights and Areas, Type of Construction, Design Occupant Load, If Fire Sprinklers are provided? Are Fire Sprinklers required? Fire resistance requirements for building elements and exterior walls based on separation distance. - Provide a listing from UL, IBC or other similar approved testing agency and include a detail showing the assembly including fasteners. - Label and note how the requirements of section 420 are provided, especially regarding horizontal and vertical separate. Provide a listing from UL, IBC or other similar approved testing agency and include a detail showing the assembly including fasteners. - On the Site Plan, Show and label the electrical service lines and equipment on the site plan. - On the Site Plan, Label the HCS with the Sewer Fee Receipt #. - Provide a listing from UL, IBC or other similar approved testing agency and include a detail showing the assembly including fasteners. - There are two A4.1 sheets, one with an additional engineer's stamp. Remove this sheet if it duplicates information. - Label and note how the requirements of section 420 are provided regarding horizontal and vertical separate. Provide a listing from UL, IBC or other similar approved testing agency and include a detail showing the assembly including fasteners. PLUMBING COMMENTS: - Label the HCS with the Sewer Fee Receipt #. - Label the Water Heater and provide a Water Heater Schedule. MECHANICAL COMMENTS: - Provide an Exhaust Fan for the range. ELECTRICAL COMMENTS: - Provide an electrical site plan or show electrical site work on the site plan. - Provide an Outdoor Lighting Code calculation. - Provide a one-line diagram for the electrical system. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/11/2021 | PCAMARE1 | OUT TO CUSTOMER | Completed |