Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - NEW
Permit Number - T21CM00795
Review Name: COMMERCIAL - NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/23/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 02/23/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM00795 3434 S Kino PW New Food Service TRANSMITTAL: February 22, 2021 This site is located in the PAD-15. Food Service is a permitted use in this zone. 1. Zoning has reviewed the building plans for compliance with DP21-0019 and although it appears that the building plans match the DP the building plans cannot be approve until the DP is approved. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
| 03/02/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | Sheet 1 1. Zoning C-2 does not match DP zoning PAD-15. Please revise accordingly. 2. Approval of the Development Package is required before this plan set may be approved. Sheet 4 (AS.1) 1. Match Lot 4 SF as shown in Development Package. Sheet 5 (AS.2) 1. Keynote 35 indicates bicycle parking adjacent to dumpster that is not shown on DP. DP shows bicycle parking where this plan shows outdoor patio seating. Please revise accordingly. 2. Clarify that Keynote 43 if seating is for eating or waiting. Project scope states there is no patio area designated for eating/drinking. Sheet 6 (AS.3) 1. Detail 7 needs the 60" min dimension to match the 7' clearance shown in the DP Detail B. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 03/15/2021 | LSHAMIS1 | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Completed | |
| 04/05/2021 | SAFEBUILT | 2ND PARTY REVIEW | REVIEW | Reqs Change | Activity Number: T21CM00795 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Denied 1. Structural steel, components and fasteners that are exposed need to be protected against corrosion in accordance with AISC 360 Section B.13 as indicated in IBC 2018 Section 2203.1. 2. Designer is to coordinate venting and drainage hole requirements for HSS tube members that are galvanized using the hot-dip galvanizing process. Provide for plugs as needed. AWS D-19.0 calls for welds on galvanized steel to be free of zinc. Field welds on galvanized parts requires the removal of the zinc coating in the area of weld. Provide zinc paint (approved by the galvanizer) and apply as required to the weld and steel area to provide protection. 3. Roof drainage and secondary drains are to comply with IBC 1502.1. 4. A Section 305/S602 is shown on Roof Plan (Drg S301) near Line A and 4. Verify and make revisions. 5. Locate Section 307 shown on Drg S601 on Roof Plan S301.Denied BUILDING REVIEW COMMENTS: Approved ELECTRICAL REVIEW COMMENTS Approved MECHANICAL REVIEW COMMENTS: Approved PLUMBING REVIEW COMMENTS: Denied Where: DFU = Drainage Fixture Units per Table defined in Pima County Industrial Wastewater Ordinance 13.36.420 (C) • The minimum retention time of 30 minutes is based on Wastewater Engineering, Treatment, Disposal and Reuse, Third Edition, Metcalf and Eddy, Inc., McGraw-Hill, Inc., page 1028. • A minimum of 25% storage is required for floatable fats, oil and grease and settled solids is required for gravity grease interceptors. • The minimum sized GGI to be installed shall be 300 gallons. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/05/2021 | LBOWERS1 | OUT TO CUSTOMER | Completed |