Permit Number: T21CM00769
Parcel: 117141830

Address:
86 W SIMPSON ST

Review Status: Active

Review Details: RESUBMITTAL

Permit Number - T21CM00769
Review Name: RESUBMITTAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/09/2022 ANY ZONING_HISTORIC REVIEW Active
08/10/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a copy of the Pima County letter of completion for combining the properties, R106.1.1. The building code compliance review is complete and may be processed for approval upon documentation submittal.
08/11/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

PROJECT: T21CM00769
92 W Simpson St
Detached Carport and Storage.
Residential (2nd Review)

TRANSMITTAL DATE: August

COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the O-3 zone (UDC 4.7.15). A single-family residence is a permitted use in this zone (Table 4.8-3).

The minimum setback is the greater of ten (10) feet, or three-fourth (3/4) the height of the structure’s wall facing each interior property line (Table 6.3-3.A).

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.
1. Based on a wall height of 12’ the required perimeter yard setback from the storage/carport to the south property line is 10’-0”, proposed setback is 5’-0”.

Historic review shall be submitted and approved prior to approval of this plan. Historic may waive perimeter yard setbacks. Historic application/requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf, and is a separate submittal from the building plans submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using Submission Type “Historic Review”.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.