Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T21CM00762
Parcel: 106071370

Address:
3302 N RENO AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM00762
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM00762
3302 N Reno Av
Carport and Porch Addition

TRANSMITTAL: February 3, 2021
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

Per UDC Article 6.4.5.D.2 Along street property lines, the following may extend into the required width. Within established areas roof overhangs may extend two feet into the required street perimeter yard. That said for a carport the post supporting the roof structure is considered a wall for applying perimeter yard requirements. As the proposed post is setback from the edge of roof 3’-9” the perimeter yard setback is measured from the allowed 2-0” encroachment which makes the proposed street perimeter yard setback 18’-3”, a DDO must be submitted and approved prior to approval of the building plans.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

The minimum setback to the back of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b.).

The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 3.11.1.B.4). In a developing area, the minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b).
02/03/2021 STEVE SHIELDS ZONING_HISTORIC REVIEW Passed
02/03/2021 SSHIELD1 ENGINEERING REVIEW Passed
02/03/2021 SSHIELD1 NPPO REVIEW Passed
02/17/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed