Permit Number: T21CM00746
Parcel: 11714297A

Address:
496 S CONVENT AV

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM00746
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/28/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT:
Permit #T21CM00746
496 S Convent St
Porch addition and solar panel installation

TRANSMITTAL: May 28, 2021

COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HO-3 zone (UDC 4.7.15).

This comment was not addressed provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf.
The minimum setback for all structures is 10 ft or ¾ the wall height, whichever is greater. The proposed solar panel and porch extension do not appear to meet required setbacks; however a full plot plan has not been provided. Historic review is required for the proposal and reduced setbacks.

The historic package review is being conducted under T21SA00071.

If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.
05/28/2021 SSHIELD1 ENGINEERING REVIEW Passed
05/28/2021 SSHIELD1 NPPO REVIEW Passed
06/07/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change The panels require a clear 3 foot fire separation distance to the property line unless the structure includes a one-hour rated wall that is placed at the edge of the roof overhang. See IBC Table 721.1(2), Items 15-1.1 to 16-1.3 for a listing of fire rated materials. Show a 3’ separation on the Site Plan or show a fire barrier detail of fire rated construction.

A professional structural engineer performance analysis is required for sizing uplift foundation and fasteners.