Permit Number: T21CM00637
Parcel: 11304023A

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM00637
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/16/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed
02/17/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM00637
1140 E Greenlee Rd
Detached Carport
Residential (1st Review)

TRANSMITTAL DATE: February 17, 2021

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2).

1. Provide a residential plot plan that meets the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

2. Per Unified Development Code (UDC) Article 6.6.3.C Accessory structures shall not exceed 12 feet in height, unless attached to a principal structure. The height of a structure with a pitched roof is measured from design grade to the midpoint of the pitched roof, see UDC Article 6.4.4.A. Based on provided information it appears that midpoint of the pitched roof is 17’-4”, a Board of Adjustment for Variance must be submitted and approved for the detached accessory structure exceeding 12’-0” in height.

3. Per Unified Development Code (UDC) Article 6.6.3.D The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. As all required information was not provided on the plot plan Zoning cannot verify the total square footage but it appears that the total gfa of accessory structures exceeds the allowed 50%, a Board of Adjustment for Variance must be submitted and approved for the detached accessory structure to exceed the 50% gfa of the principal structure.

Board of Adjustment submittal requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966
02/17/2021 SSHIELD1 ENGINEERING REVIEW Passed