Permit Number: T21CM00531
Parcel: Unknown

Address:
665 N SWAN RD

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T21CM00531
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/28/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. The applicable codes for the project are the 2018 editions of the International Code and the 2017 National Electric Code. Revise the Applicable Code information on sheet T1.0, the Energy Conservation Info on sheet A1.0, and item 1 of the Mechanical Notes on sheet ME to indicate the correct codes for this project.
2. Demonstrate energy code compliance for the addition to the building envelope using calculations based on the current code. Reference: Section C502.1, International Energy Conservation Code 2018.
3. Show that the specified heat pump for the addition complies with the requirements of Section C403, IECC 2018. Reference: Section C502.2.3, IECC 2018.
4. Provide heating and cooling load calculations to justify the heating/cooling capacities of the specified HVAC units. Reference: Section C403.1.1 and C502.2.3, IECC 2018.
5. Provide calculations to verify that adequate ventilation will be provided for the addition. Reference: Section 403.3.1.1, IMC 2018.
6. Provide locking access port caps for the condensing units per Section 1101.10, IMC 2018 or locate the condensing unit in a controlled space.
01/28/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Provide calculations to show that the size of the overflow scupper has a drainage capacity equal to that of the primary scupper. Reference: Sections 1106.5 and 1108.3, IPC 2018.
01/28/2021 ROBERT SHERRY WATER REVIEW Completed
02/08/2021 JPEELDA1 FIRE REVIEW Approved
02/09/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
02/10/2021 STEVE SHIELDS ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
T21CM00531
665 N Swan Rd
Office Expansion

TRANSMITTAL: February 10, 2021
This site is located in the O-3 zone (UDC 4.7.15). Administrative and Professional Office is a permitted use in this zone (Table 4.8-4) Subject to Use Specific Standard 4.9.13.K.

1. Zoning has reviewed the building plans but cannot approve until a Development Package meeting the requirements of Administrative Manual 2-06 has been submitted and approved. Based on the expansion calculation provided on this building plan, 37% the site will need to be brought up to full code compliance to include but not limited to, vehicle & bicycle parking, pedestrian circulation, solid waste, etc.

2. Provide a copy of the last approved development package/site plan with your development package submittal.

3. Provide a copy of Rezoning case C9-75-11 with your development package submittal.

If you have any questions about this transmittal, please contact Elisa Hamblin, (520) 837-4966 or Elisa.Hamblin @tucsonaz.gov
02/16/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet S1.0; General Framing Notes/General Foundation Notes: Please revise all references to the 2012 IBC.
2. General: Please provide structural calculations for the addition framing and foundation.
3. General: Please provide a Special Inspections Certificate with Parts A and B completed.
4. General: Please provide written responses to all review comments.
02/16/2021 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Reqs Change
02/18/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change See zoning comments about the need of a development package approved before approving the building plans.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
02/22/2021 PCAMARE1 OUT TO CUSTOMER Completed