Permit Number: T21CM00525
Parcel: 106061240

Address:
1262 W KNOX PL

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM00525
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/22/2021 SBLOOD1 ENGINEERING REVIEW Passed
02/09/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM00525
1262 W Knox Pl
Detached Garage
Residential (1st Review)

TRANSMITTAL DATE: February 9, 2021

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Provide a perimeter yard setback dimension from the proposed garage to the north property line. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 Zones, R-1 Zone, the required perimeter yard setback is 6’-0” or 2/3 the height of the propose exterior building wall. This height is measured from design grade to the highest point of the wall. Based on a wall height of 13’-0” the required perimeter yard setback is 8’-8”.

2. As a wall height was not provided for the west wall perimeter yard setbacks could not be verified. At a minimum per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 Zones, R-1 Zone, the required perimeter yard setback is 6’-0”.

For comments 1 & 2 per UDC Article 6.6.2.D a neighbor’s signoff can reduce the perimeter yard setback down to 0’-0”. If you elect to use the neighbor signoff the following verbiage shall be provided on the plot plan for the owners of the properties at 1272 W Knox Pl, David or Stephanie Miller, and 1271 W McMillian St, Thanh or Vuong Nguyen to sign. If the adjacent property owners will not sign a Design Development Options (DDO) will need to be processed and approved to reduce the perimeter yard setbacks. DDO requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf

3. Per UDC Article 6.6.3.C the maximum allowed height for a detached accessory structure in a residential zone is 12’-0”. Per UDC Article 6.4.4 this height is measured from design grade to the midpoint of a pitched roof. Provide a building height dimension on the building elevations. If this height exceeds 12-0” a Board of Adjustment for Variance is required. Board of Adjustment requirements can be found at: https://www.tucsonaz.gov/files/pdsd/codes/Zoning_Administration_Application_BA_fillable.pdf

4. Per UDC Article 6.6.3.D The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure. Accessory structures less than 200 square feet gfa are exempt from this requirement. The total square footage of the proposed garage and the existing shed = 872 sq. ft. which exceeds the 50% allowed square footage of the main dwelling. a Board of Adjustment for Variance is required.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966
02/09/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change SHOW THE LOCATIOPN OF THE ELECTRICAL SERVICE PANEL AND FEEDER TO THE GARAGE SUB PANEL ON THE SITE PLAN.

PROVIDE STAMPED TRUSS PLANS BEFORE INSTALATION.
02/23/2021 ANDREW CONNOR NPPO REVIEW Passed
03/23/2021 LBOWERS1 ZONING_HISTORIC REVIEW Passed