Permit Number: T21CM00420
Parcel: 122163550

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T21CM00420
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/27/2021 PCAMARE1 ENGINEERING REVIEW Passed
02/03/2021 ANDREW CONNOR NPPO REVIEW Passed
02/08/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed
02/09/2021 STEVE SHIELDS ZONING_HISTORIC REVIEW Passed
02/09/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

PROJECT: T21CM00420
3555 E Hampton St
Metal Fence, Detached Carport, Conversion of SFR to Duplex
Residential (1st Review)

TRANSMITTAL DATE: February 9, 2021

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

1. COMMENT: Provide permit documents that converted the single family residence to a duplex.

COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment (UDC Section 3.10.1).

2. Per Unified Development Code (UDC) Article 6.6.3.B Detached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line. That said the carport shown on the plans is not allowed to be partially within the front yard.

3. Per UDC Article 6.6.2.D you may request that the owner of the property to the east sign a setback reduction waiver to reduce the side yard setback to 0’-0”. If the owner will not sign the waiver a Board of Adjustment for Variance is required to reduce the setback to 0’-0”. If the carport is relocated to be a minimum 1’-0” from the east property line a DDO can reduce the setback.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of less than 9’-0” the required perimeter yard setback from the carport to the east property line is 6’-0”, proposed is 0’-0”.

COMMENTS: the following comment is relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

4. The maximum height of a wall or fence within a perimeter yard shall be six (6) feet (UDC Section 6.6.2.I). The maximum height of a retaining wall is ten (10) feet from design grade and no higher than six (6) feet measured from the top of the retaining portion of the wall (UDC Section 6.6.2.I.2). Proposed fence runs from 6’-1” to 6’-4”.

To avoid going through two (2) separate processes the above issues can be processed through the Board of Adjustment process if you elect to do so.




If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966