Permit Number: T21CM00409
Parcel: 124051470

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM00409
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/18/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set for review.

Update the site plan to show all utility lines on property. Include a minimum 1" water yard pipe.
10/21/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM00409
420 N Santa Rita Ave
Addition to Existing SFR
Residential (4th Review)

TRANSMITTAL DATE: October 21, 2021

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2).

Until DDO T21SA00407 is approved and the appeal period has expired Zoning cannot approve the building plans.

This proposed addition does not meet the minimum setback standards, a DDO will be required. The minimum setback on the north, east, and south side of the property are the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

1. Based on a wall height of 14’-4’ the required perimeter yard setback from the proposed addition to the south property line is 9’-6”, proposed setback is 4’-0”.

2. Based on a wall height of 14’-4’ the required perimeter yard setback from the proposed addition to the east property line is 9’-6”, proposed setback is 4’-0”.

3. Based on a wall height of 9-10’ the required perimeter yard setback from the proposed porch to the east property line is 6’-6”, proposed setback is 6’-4”

If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.