Permit Number: T21CM00409
Parcel: 124051470

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM00409
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/31/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide completed plans for Building review.
09/01/2021 SBLOOD1 ENGINEERING REVIEW Passed
09/02/2021 SROGERS2 NPPO REVIEW Passed
09/02/2021 SAMUEL ROGERS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Samuel Rogers, Planner
PDSD Zoning Review

PROJECT: T21CM00409
420 N Santa Rita Ave
Addition to Existing SFR
Residential (2nd Review)

TRANSMITTAL DATE: August 31, 2021

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2).

1. The proposed onsite parking space does not meet minimum length requirements. Per UDC 7.4.6.D.2.C: A parallel parking space must be eight feet wide and 23 feet in length, except as follows. A parallel parking space can be reduced to 18 feet in length if the space is located immediately adjacent to a driveway , access lane , PAAL , alley , or street intersection and the parking space is designed to provide maneuvering area on at least one end.
2. This proposed addition does not meet the minimum setback standards, a DDO will be required. The minimum setback on the north, east, and south side of the property are the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).
a. The proposed set back on the north side of the property measured from the post supporting the proposed porch is not shown.
b. The proposed height of the addition is 15’-2” and requires a 10’ setback. The proposed setback on the east and south sides of the property are 4’.
3. The minimum setback on the west side of the property is 20’ or one and one-half the height of the proposed wall (H), measured from the street property line , whichever is greater. The addition has a proposed setback on the west is 10.4’, a DDO will be required.
4. There are two elevations labeled as the “West Elevation”