Permit Number: T21CM00355
Parcel: 12111121B

Review Status: Completed

Review Details: 3RD PARTY REVIEW - RESIDENTIAL

Permit Number - T21CM00355
Review Name: 3RD PARTY REVIEW - RESIDENTIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/27/2021 ARUIZ1 3RD PARTY REVIEW-COMMERCIAL REVIEW Completed
04/27/2021 ARUIZ1 3RD PARTY REVIEW-COMMERCIAL AT 3RD PARTY OFFICE Completed
05/05/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM00355
1402 N Swan Rd
4 Unit Multifamily Development
Residential (2nd Review)

TRANSMITTAL DATE: May 5, 2021

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2).

1. As you are proposing 4 dwelling units on a single site the site is considered multi-family and a nonresidential use, See UDC Articles 6.3.3.C & D and 11.3.7.3. That said a Development Package (DP) meeting the requirements of Administrative Manual 2-06 must be submitted and approved prior to any building permit approval. The DP is a separate submittal. The DP will be required at the minimum, but not limited to, to meet the requirements of Unified Development Code Articles 7.4, 7.6, Technical Standards Manual Sections 7 & 8.

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall, see UDC Article 6.4.5.B & Figure 6.4.5-A. As correct dimensions were not provided on the elevations exact setback requirements cannot be verified. Comments below are based on the dimensions provided on the elevations.

2. As this property boarders on Swan Rd and Swan is designated as an Arterial on the COT MS&R map the street perimeter yard setbacks are based on UDC Article 6.4.5.C.2 Developing Area. For Swan the street perimeter yard setback is 21’ or the height of the proposed exterior building wall, greater of the two, measured from the back of future curb. For Fairmount the street perimeter yard setback is 21’ or the height of the proposed exterior building wall, greater of the two, measured from the outside edge of the nearest adjacent travel lane. Show the correct street perimeter yard setbacks on the plan

The minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of structure’s wall facing each interior property line (Table 6.3-2.A).
3. Based on a wall height of 20’-8” the required perimeter yard setback from the proposed duplex to the east property line 15’-6”, proposed is 12’-0”.

DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin @tucsonaz.gov or (520) 837-4966
05/05/2021 SSHIELD1 NPPO REVIEW Passed
05/14/2021 SBLOOD1 ENGINEERING REVIEW Reqs Change See zoning comments about need for DP

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
05/17/2021 PCAMARE1 OUT TO CUSTOMER Completed