Permit Number: T21CM00299
Parcel: 123071180

Address:
1220 N NORRIS AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T21CM00299
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T21CM00299
1220 N Norris Ave
Bedroom, Wet Bar & Garage Addition (3rd Review)

TRANSMITTAL October 13, 2021

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5-.9.

1. This comment was not addressed correctly. All vehicle parking is required to be in the side or rear yard. The 2 vehicle parking spaces shown in the front yard to not meet this require. Once the correct parking spaces are provided demonstrate on the plan how the dustproofing requirement is met. Per UDC TABLE 4.8-2: PERMITTED USES - URBAN RESIDENTIAL ZONES, R-1 ZONE, Single-family , Detached, Use Specific Standards 4.9.7.B.5 – 9 apply. That said Use Specific Standards 4.9.7.B.7 states “For any new single-family dwelling in the R-1 zone with five bedrooms, three parking spaces are required. For every bedroom over five, one additional space is required for each bedroom . For all single-family dwellings in the R-1 zone with five or more bedrooms, and for all lots containing two or more single-family dwellings, with the second dwelling having more than one bedroom, all parking spaces must be located on-site, either in a side or rear perimeter yard. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. A parking area is not required to be developed to a commercial standard. A dustproof parking surface is required to at least a minimum of two inches of compacted pea gravel. An existing covered residential parking area may be used.” As the proposed SFR has six (6) bedrooms you must provide 4 vehicle parking spaces in a side or rear yard with surfacing meeting the above requirements. The “Wet Bar” counts as bedroom base on the bedroom definition found in UDC Article 11.4.3. Show the required 4 vehicle parking spaces on the plot plan and address the surfacing requirements.

2. Per UDC Article 6.4.5.B & Figure 6.4.5-A perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall. Based on the type of construction this dimension is from design grade to the point where the wall meets the underside of the roof overhang. As these dimensions were not provided Zoning as used a measurement using Bluebeam software. The following comments are in relationship to required interior perimeter yard setbacks. Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-1 ZONE, RESIDENTILAL USE TO RESIDENTIAL ZONE, the required interior perimeter yard setbacks are 6’-0” or 2/3 the height of the exterior wall.
Based on a wall height of 11’-5” the required perimeter yard setback from the proposed bedroom wet bar to the south property line is 7’-8”, proposed setback is 6’-0”.

The above proposed perimeter yard setbacks will require approval through the Design Development Options (DDO) process. The DDO is a separate review submittal and is submitted at: https://www.tucsonaz.gov/pdsd-filedrop. Use the “Submission Type*, Zoning Administration: Design Development Option/Peddlers/etc.*” located under “Special Applications”. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf.
The DDO must be submitted and approved prior to the approval of the building permit.


If you have any questions about this transmittal, please contact Elisa Hamblin, Elisa.Hamblin@tucsonaz.gov.