| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2021 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 03/25/2021 | NMARTEL1 | ZONING | REVIEW | Passed | |
| 04/08/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Show the location of the sink on the plan. Show a receptacle outlet within 3’ of each lavatory basin in each bathroom, E3901.6. Show Bathroom receptacles on a separate 20 AMP circuit (dedicated) with outlets at no other location, E3703.4 and E3901.6. Show at least one wall switch controlled light in bathrooms, E3903.3. Show bathroom (without a window) exhaust fan locations with minimum 50 CFM rating and duct to the exterior, R303.3 and M1505. |
| 04/30/2021 | AWARNER1 | NPPO | REVIEW | Passed |