01/27/2021 ANDREW CONNOR NPPO REVIEW Passed
01/27/2021 PCAMARE1 ENGINEERING REVIEW Completed
02/03/2021 NMARTEL1 ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

Nicholas Martell, Planner
T21CM00239
Bathroom Addition
420 E Speedway


TRANSMITTAL: 02/03/2021
COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8).

This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The proposed addition appears to be on the southern property line. HPZ review required for setback modification. If HPZ does not grant the reduction in setbacks a variance may be necessary.

Historic requirements, checklist and applications can be found here: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf

If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov.
02/03/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed