Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T21CM00172
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/15/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | 1. Provide a Development Package showing the proposed canopy structure. 2. Ensure the canopy edge is set back 1 foot from the PAAL or exceeds 15 feet clearance. |
| 03/16/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. Sheet 2 of 9; Boxed Note: A note indicates "All Construction/Installation is to comply with the following: 2018 IRC". Please revise to the IBC. 2. General: Please provide structural calculations, general structural notes, details, material specifications, and sections as required at the new canopy. These require a registered design professional to seal, sign, and date all submittal documents. 3. General: On the drawings, please provide the new canopy SF, construction type, and occupancy classification. 4. General: Please provide a Special Inspections Certificate with Parts A and B completed. 5. General: Please provide written responses to all review comments. |
| 03/16/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM00172 4793 S Julian Ave Building Expansion TRANSMITTAL: March 3, 2021 This site is located in the C-1 zone (UDC 4.7.20). . 1. As this is an commercial site and a structure, solar canopy is being added to the site a Development Package (DP), commercial site plan, meeting the requirements of the Minor Changes to Commercial/Industrial Site check list, is required. Requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf This DP will needs to be submitted and approved prior to approval of this solar plans. The required DP is a separate submittal from the building plan. Once the DP has been submitted and approved Zoning will be able to approve this plan. If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov |
| 03/16/2021 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 03/16/2021 | LBOWERS1 | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. Electrical plan review is Denied as follows:1. Verify that the General Duty AC Disconnect Swithch is rated as "Suitable for use as Service Equipment" as required per NEC art 690.13C. 2. Provide a grounding detail for the PV racking and the steel canopys.NEC 690 Part V. Grounding and Bonding. Ref 2017 NEC |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/17/2021 | IMONSHI1 | OUT TO CUSTOMER | Completed |