Permit Review Detail
Review Status: Completed
Review Details: WALLS
Permit Number - T21BU00107
Review Name: WALLS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 03/22/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Passed | |
| 04/05/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21BU00107 1021 N 3rd Ave Metal perimeter Fence TRANSMITTAL: April 5, 2021 COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). This site is located in the HR-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. As a residential plot plan meeting the requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf, was not provided and it is not clear where the property lines are additional comments maybe forth coming. 1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). That said it appears that a 6’-6” fence is proposed along the south property line. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six (6) feet 2. The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). As N Hoff Ave is a named alley it is considered to be a street for the purpose of perimeter yard setbacks. That said it appears that a 6’-6” fence is proposed along the west property line. Per UDC Article 6.6.2.I The maximum height of a wall or fence within a perimeter yard shall be six (6) feet. Historic review is required for the proposed fence additions and maybe able to waive the setback/fence height requirements. Historic application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/Preservation/HPZ_Review_Application_Package_2020.pdf, and shall be a separate submittal at: https://www.tucsonaz.gov/pdsd-filedrop, using the Special Applications, Historic Review selection. If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov. |
| 04/05/2021 | STEVE SHIELDS | ZONING_HISTORIC | REVIEW | Needs Review |