Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T20PRE0189
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/06/2021 | MROSS2 | COT NON-DSD | FIRE | Completed | No comments at this time. |
01/13/2021 | SBLOOD1 | ENGINEERING | REVIEW | Completed | No comments |
01/13/2021 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T20PRE0189 - 12898 S HOUGHTON RD - Site Equip Well H-002B 1. Tucson Water has no adverse comments regarding this proposed development. 2. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |
01/14/2021 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0189 Address: 12898 S Houghton Rd Parcel(s): 30501014B Zoning: RX-1 Existing Use: Utilities – Distribution System Proposed Use: (same) (Special Exception) TRANSMITTAL DATE: January 14, 2021 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The existing use of Utilities – Distribution System is subject to a Zoning Examiner Special Exception procedure and use specific standards 4.9.11.A.1, .2, .5, .8, .9, .11., which are listed below. --1. The setback of the facility, including walls or equipment, shall be 20 feet from any adjacent residential zone. --2. Where a facility is not enclosed within a building, the surrounding screen shall be used as the building wall for the purposes of setbacks. --5. The use shall not have any service or storage yards. --8. Any building housing such facility shall be in keeping with the character of the zone in which it is located. The Design Review Board (DRB) shall review all applications and make recommendations to the Zoning Examiner. The DRB shall review architectural style, building elevations, materials on exterior facades, color schemes, new mechanical equipment locations, lighting of outdoor areas, window locations and types, screening, landscaping, vehicular use areas, and other contributing design features. --9. The use shall be located wholly within an enclosed building or within an area enclosed on all sides with a masonry wall or compact evergreen hedge, not less than six feet, nor more than ten feet, in height. --11. The use shall be limited to water pumping and storage facilities, telephone exchanges, and power substations with an input voltage of no greater than 138 kilovolts. 3. As the site is currently nonconforming and an expansion is proposed on site, a Special Exception is required. Please work with John.Beall@tucsonaaz.gov on the Special Exceptions. 4. Use specific standards may be modified through the Special Exception process. The items of concern include the setbacks and the solid masonry wall. 5. As a new structure is proposed on site, special exception, development package and building plan submittals are required. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |
12/22/2020 | ACONNOR1 | COT NON-DSD | TRAFFIC | Completed | No comments at this time. |
12/22/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | No comments. |