Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Plan Number: T20PRE0178
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T20PRE0178
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed No comments at this time.
12/16/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Not applicable.
12/17/2020 GDAURIA1 COT NON-DSD FIRE Completed
12/22/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0178
Address: 1937 N Nancy Rose Bl
Parcel(s): 121-09-1680
Zoning: R-1
Existing Use: Utilities – Distribution System
Proposed Use: [same]

TRANSMITTAL DATE: December 21, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The existing use of Utilities – Distribution System is subject to a Zoning Examiner Special Exception procedure and use specific standards 4.9.11.A.1, .2, .5, .8, .9, .11., which are listed below.
--1. The setback of the facility, including walls or equipment, shall be 20 feet from any adjacent residential zone.
--2. Where a facility is not enclosed within a building, the surrounding screen shall be used as the building wall for the purposes of setbacks.
--5. The use shall not have any service or storage yards.
--8. Any building housing such facility shall be in keeping with the character of the zone in which it is located. The Design Review Board (DRB) shall review all applications and make recommendations to the Zoning Examiner. The DRB shall review architectural style, building elevations, materials on exterior facades, color schemes, new mechanical equipment locations, lighting of outdoor areas, window locations and types, screening, landscaping, vehicular use areas, and other contributing design features.
--9. The use shall be located wholly within an enclosed building or within an area enclosed on all sides with a masonry wall or compact evergreen hedge, not less than six feet, nor more than ten feet, in height.
--11. The use shall be limited to water pumping and storage facilities, telephone exchanges, and power substations with an input voltage of no greater than 138 kilovolts.
3. As the site is currently nonconforming and an expansion is proposed on site, a Special Exception is required. Please work with John.Beall@tucsonaaz.gov on the Special Exceptions.
4. Use specific standards may be modified through the Special Exception process. The items of concern include the street setback and the solid masonry wall.
5. As a new structure is proposed on site, special exception, development package and building plan submittals are required.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov.
12/22/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0178 - 1937 N NANCY ROSE BL - Site Equip Well B-052B

1. Tucson Water has no adverse comments to this development.

2. Any questions, comments or concerns about these projects may be directed to:
Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
12/22/2020 SBLOOD1 ENGINEERING REVIEW Completed 1. Maximize water harvesting in landscaped areas.

Stephen Blood
stephen.blood@tucsonaz.gov
12/22/2020 ELISA HAMBLIN ZONING REVIEW Completed Prior comments from John Beall, Entitlements Section Manager, from meeting Sept 2020
REZONING/SPECIAL EXCEPTION
PRESUBMITTAL PREAPPLICATION REVIEW



CASE NUMBER: T20PRE0120
(9-30-20 1937 N Nancy Rose Blvd)

APPLICANT NAME: THE PLANNING CENTER – LEXY WELLOTT

PHONE: 623-6146 E-MAIL: LWELLOTT@AZPLANNINGCENTER.COM

PROJECT DESCRIPTION & LOCATION: 1937 N. NANCY ROSE BLVD – THE PROPOSED SPECIAL EXCEPTION IS FOR EXPANSION OF EXISTING TUCSON WATER WELL SITE.



APPLICABLE PLAN POLICIES:
Plan Tucson contains a variety of elements that are categories in four focus areas, including the Social Environment, the Economic Environment, the Natural Environment, and the Built Environment. Each focus area contains specific goals and each element contains specific policies.
The site lies within the Neighborhoods with Greater Infill Potential building block where there is potential for new development and redevelopment. These neighborhoods include a mix of such uses as a variety of housing types, grocery stores and other retail and services, public schools, parks and recreational facilities, and multi-modal transportation choices.

LT28.1.3 – Improve the appearance of above-ground utilities and structures.

LT28.2.12 – Support environmentally sensitive design that protects the integrity of existing neighborhoods, complements adjacent land uses, and enhances the overall function and visual quality of the street, adjacent properties, and the community.

Arcadia – Alamo Area Plan (AAAP)
Goal: Preserve and protect the integrity of established low-density neighborhoods.

Defines the following -
Buffering: masonry walls, landscaping to mitigate impact of more intense development to less intense uses.
Screening: opaque barrier designed and constructed to conceal uses used for storage, mechanical equipment from street and public view.

Design Guidelines – address hours of operation for service; use of enhanced landscaping along public streets such as understory shrubs and ground cover; screen water pumping station with landscaping and minimum 6-foot masonry wall.

Applicant to demonstrate compliance with AAAP General Design Guidelines and Policies.



ANALYSIS:
The proposed Zoning Examiner Special Exception is for an expansion of a Tucson Water well to be located on an approximately 0.19-acre parcel in the R-1 zone district. The R-1 zone district allows for utility distribution through the Zoning Examiner Special Exception Procedure and must be compliant with the use specific standards called out in Section 4.9.11 of the Unified Development Code.

The property is an existing City of Tucson well site. It is located within an existing R-1 residential neighborhood. The existing well site fencing appears to have slats in the chain-link fence around the perimeter of the lot / water well site. Fence height is not called out on site plan. The application calls a height of 20-feet but is not identified on the site plan where this height is located, with the setback distance from the adjacent residential zone to the south identified as 10-feet.

The policy direction of Plan Tucson and the Arcadia – Alamo Area Plan each have policies that ensure sensitive design to development adjacent to established neighborhoods. A plan amendment is not required. Possible mitigation measures may be required to help buffer the use from the residential properties adjacent to the property, including additional landscaping and screening, masonry walls, increase setbacks for heights greater than 20-feet, and potential dust mitigation. Discuss hours of service for well site.

Staff recommends applicant provide a more refined concept plan that indicates a little more clearly the proposed landscape plan and screening for the well site. Be sure to call out on the concept plan, height of all buildings, antennas, and well pump mechanisms, as well as proposed materials.

Be sure to look at the Use Specific Standards in Section 4.9.11 of the Unified Development Code (UDC) and if any deviation will be necessary please bring that back to staff at a second Presubmittal meeting if need be. [6-foot screen along streets with 6-foot wall against residences and 10-foot landscape borders street and interior]