Plan Number: T20PRE0177
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T20PRE0177
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed 8.7.3. FLEXIBLE LOT DEVELOPMENT (FLD)

Landscaping, Screening and Wall Requirements

1. FLD projects shall comply with Section 7.6, Landscaping and Screening Standards, except as otherwise provided by this section.

2. One canopy tree shall be provided every 40 feet of pedestrian circulation systems, excluding crossings with streets, alleys, and driveways. If providing canopy trees every 40 feet is not achievable, the applicant shall:

a. Provide the equivalent number of trees that would be obtained using the 40-foot increment measure; and,

b. Distribute the trees within the FLD project site along pedestrian circulation systems and within functional open space areas.

3. Landscape plans shall incorporate water-conserving design as defined in Section 7.6.6, Use of Water, and as described in the Technical Standards Manual.

4. Water harvesting techniques shall be incorporated as part of the landscape design based on the Water Harvesting Guidance Manual prepared for the City of Tucson Transportation Department Stormwater Section.

5. Mechanical equipment, utility boxes, irrigation equipment and similar elements shall be screened from adjacent streets exterior to the project and from adjacent existing residential development. Screening shall be architecturally integrated with the overall design of the FLD.

6. If a perimeter wall is proposed along an existing public right-of-way, it shall be constructed of, or painted with, graffiti-resistant materials. The wall shall incorporate one or more of the following decorative materials:

a. Tile;

b. Stone;

c. Brick;

d. Adobe;

e. A textured material such as stucco or plaster; or,

f. Metal.
12/16/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirements will apply.

Sidewalk required along frontage along Blacklidge, and Monte Vista

No TIA required.

ADT of 5 acceptable for Mobilre Home

Requirements for private street modifications will be defered to PDSD.
12/17/2020 GDAURIA1 COT NON-DSD FIRE Completed * Hydrants required within 400' of all exterior portions of future homes (600' if sprinklered).
12/22/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0177
Address: 4025 E Monte Vista Dr
Parcel(s): 11006071A, 11006081A
Zoning: MH-1, MH-2, R-3
Existing Use: Single-family residence, Mobile home park
Proposed Use: Flexible Lot Development

TRANSMITTAL DATE: December 21, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a Flexible Lot Development, which is permitted in the MH-1, MH-2 and R-3 zones, subject to use-specific standards 8.7.3.
3. When a site is split by different zones, the site may be developed in a unified manner, but the development standards for each zone must still be met. The proposed density on the MH-1 and MH-2 portion does not meet FLD density standards. If a rezoning to R-3 is proposed, the density appears to be permissible.
4. Functional open space and parking appear to meet requirements.
5. The following setbacks apply to perimeter yard setbacks on the boundary of the development:
a. North (Blacklidge Dr) and South (Monte Vista Dr): 21 ft or building wall height, measured from outside edge of adjacent travel lane
b. East and West (residential use to residential zone): 6 ft or 2/3 building wall height
6. An Architectural Variation Plan will be required in accordance with UDC Article 8.7.3.M.1.
7. Privacy Mitigation will be required in accordance with UDC Article 8.7.3.M.2.b. for all boundaries to the east and west, except for the 2-story apartments to the southwest of the site.
8. A lot combination processed with Pima County will be required.
9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov.
12/22/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T20PRE0177 - 4025 E MONTE VISTA DR - SiteFLD Oasis MHP Subdivision

1. There is an existing 6" cement asbestos water main (PN 006-1962) in Monte Vista Drive, and an existing 6" cement asbestos water main (PN 032-1965) in Blacklidge Drive that can serve this development.
2. Water pressure in this area is estimated to be in the 64-76 psi range, based on the elevation of this site. I am not aware of any water pressure issues in this area.
3. Connecting the two existing 6" water mains with a new 8" on-site water main is likely to be sufficient to serve this development, but this cannot be stated as a fact until both of the following occur:
a. The need for any new fire hydrants and the required fire flow has been determined.
b. The proposed piping configuration is hydraulically modeled during Tucson Water's Master Plan Review process.
4. The design of all new water main(s) will need to go through Tucson Water's Master Plan and Design Plan review processes.
5. All new on-site water main(s) will need to be in new water line easements that are a minimum of 15 ft. wide.
6. Any questions, comments or concerns about these projects may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
12/22/2020 SBLOOD1 ENGINEERING REVIEW Completed 1. Site is within FEMA Flood Zone Xs-100yr. FUP is required and FFE needs to be 1' above BFE.
2. Alternate Location for the eastern side sidewalk will need a TSMR.
3. Maximize Water harvesting.

Stephen Blood