11/16/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | |
11/24/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
12/07/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard requirements will apply. Close any unused curb cuts. New sidewalks where none exist. New pedestrian ramp at corner of Alvernon, and Lee to meet current PAG standards. |
12/09/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0170 Address: 1601 N Alvernon Wy Parcel(s): 12218025B Zoning: O-2 Existing Use: Vacant Proposed Use: Commercial TRANSMITTAL DATE: December 9, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for development of a “commercial plaza” (also described as “office shell”) on a vacant property. Additional information is needed regarding the proposed use to determine whether the use is permitted in the zone or if any use-specific standards apply. 3. Additional information regarding uses can be found in UDC Section 4.8.5. Dimensional standards can be found in Section 6.3.4. Parking requirements can be found in Section 7.4.4. 4. The required minimum setbacks are as follows: Alvernon Wy is 21 ft or the wall height, as measured from the back of future curb; Lee St is 21 ft or the wall height, as measured from the outside edge of adjacent travel lane; interior to the north and west are 10 ft or ¾ of the wall height. Additional information is needed regarding the proposed wall height to determine if setbacks are being met. 5. The rezoning case (C9-07-10) associated with this site has an approved preliminary development plan and rezoning conditions. The proposal must be in conformance with the plan and conditions, otherwise an amendment will be required. Please contact John Beall, Entitlements Section Manager at john.beall@tucsonaz.gov to discuss further. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov. |
12/09/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Floodplain compliance required. 2. Update solid waste volume calculation. |
12/10/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 230 - 300 pm - T20PRE0170 - 1601 N ALVERNON WY - Site Commercial Plaza 1. This parcel is currently served by a ¾ inch copper water service line connected to the 8" cement asbestos water main in Lee Street. 2. The largest water meter that can be connected to this ¾ inch copper water service line is a ¾" water meter, which can serve a maximum of 153 2018 IPC water fixture units. 3. Should this project require more water than what a ¾" water meter can deliver, please contact Tucson Water's New Services Section by sending an email to TW_Common@tucsonaz.gov. 4. Tucson Water has no adverse comments to this development. 5. Any questions, comments or concerns about these projects may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |