Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T20PRE0161
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T20PRE0161
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/10/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed If applicable: Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
11/12/2020 GDAURIA1 COT NON-DSD FIRE Completed * Hydrants to be located on fire access roads with travel distance not to exceed 400' to any exterior portion of any structure (600' if sprinklered).
* Describe High Bay Shelving (storage exceeding 12' ht adds additional requirements).
* Buidings greater than 30' ht require aerial fire access complying with IFC D105.
11/30/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard reqwuirements will apply. New sidewalk, driveways will be required along frontage of proposed project. Close any unused curb cuts.

Zelin Canchola
Transportation and Mobility Engineering
12/02/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0161
Address: 2005, 2015, 2025 W Highway Dr, 2028, 1994 W Weymouth St
Parcel(s): 103090290, 103090300, 103090310, 103090230, 103090240, 103090250
Zoning: I-1
Existing Use: Industrial
Proposed Use: Mixed Use

TRANSMITTAL DATE: December 2, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a change of use from an existing industrial area to a mixed use development consisting of Religious, Office, Storage and other uses. Additional information is needed regarding some of the uses on site, as they may be associated with the Religious use.
3. As a change of use, full code compliance will be required for landscape, parking, pedestrian circulation and other standards.
4. Please note, parking requirements are as follows: For multiple or mixed use development where Religious Use is the principal land use, the total number of motor vehicle spaces required is the number required for the Religious Use or the sum of those required for other uses on the site, whichever is greater.
5. Pedestrian access (sidewalk, crosswalk) is required from each street of which the development has frontage and throughout the development.
6. Any proposed demolition of existing structures on site will require relevant demolition permits.
7. A lot combination processed with Pima County will be required.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov.
12/02/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0161 - 2005 W HIGHWAY DR - Site GAP Ministries

Tucson Water has no adverse comments regarding this proposed development. Any questions, comments or concerns about these projects may be directed to:
Fabien Elenes, Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2202
Fabien.Elenes@tucsonaz.gov
12/02/2020 SBLOOD1 ENGINEERING REVIEW Completed 1. Provide on plans waste stream calculations per City of Tucson (COT) Technical Standards Manual (TSM) section 8-01.8.0. Show trash enclosures required from waste stream calculations.
2. This site is within a critical basin. Critical basin detention and 5-year threshold retention is required. A drainage report is required.
3. Show complete pedestrian circulation path to adjacent streets.
4. Maximize water harvesting.

Stephen Blood
stephen.blood@tucsonaz.gov