Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T20PRE0161
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/10/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | If applicable: Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
11/12/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * Hydrants to be located on fire access roads with travel distance not to exceed 400' to any exterior portion of any structure (600' if sprinklered). * Describe High Bay Shelving (storage exceeding 12' ht adds additional requirements). * Buidings greater than 30' ht require aerial fire access complying with IFC D105. |
11/30/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard reqwuirements will apply. New sidewalk, driveways will be required along frontage of proposed project. Close any unused curb cuts. Zelin Canchola Transportation and Mobility Engineering |
12/02/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0161 Address: 2005, 2015, 2025 W Highway Dr, 2028, 1994 W Weymouth St Parcel(s): 103090290, 103090300, 103090310, 103090230, 103090240, 103090250 Zoning: I-1 Existing Use: Industrial Proposed Use: Mixed Use TRANSMITTAL DATE: December 2, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for a change of use from an existing industrial area to a mixed use development consisting of Religious, Office, Storage and other uses. Additional information is needed regarding some of the uses on site, as they may be associated with the Religious use. 3. As a change of use, full code compliance will be required for landscape, parking, pedestrian circulation and other standards. 4. Please note, parking requirements are as follows: For multiple or mixed use development where Religious Use is the principal land use, the total number of motor vehicle spaces required is the number required for the Religious Use or the sum of those required for other uses on the site, whichever is greater. 5. Pedestrian access (sidewalk, crosswalk) is required from each street of which the development has frontage and throughout the development. 6. Any proposed demolition of existing structures on site will require relevant demolition permits. 7. A lot combination processed with Pima County will be required. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov. |
12/02/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T20PRE0161 - 2005 W HIGHWAY DR - Site GAP Ministries Tucson Water has no adverse comments regarding this proposed development. Any questions, comments or concerns about these projects may be directed to: Fabien Elenes, Engineering Associate Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 Fabien.Elenes@tucsonaz.gov |
12/02/2020 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Provide on plans waste stream calculations per City of Tucson (COT) Technical Standards Manual (TSM) section 8-01.8.0. Show trash enclosures required from waste stream calculations. 2. This site is within a critical basin. Critical basin detention and 5-year threshold retention is required. A drainage report is required. 3. Show complete pedestrian circulation path to adjacent streets. 4. Maximize water harvesting. Stephen Blood stephen.blood@tucsonaz.gov |