Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: T20PRE0149
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T20PRE0149
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
10/30/2020 GDAURIA1 COT NON-DSD FIRE Completed
11/04/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0149
Address: 3050 E Fort Lowell Rd
Parcel(s): 11204369A
Zoning: C-1
Existing Use: Vacant
Proposed Use: Commercial – Food Service with Alcoholic Beverage Service (accessory)

TRANSMITTAL DATE: November 4, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposed use is Food Service with Alcoholic Beverage Service as an accessory use is permitted in the C-1 zone subject to use-specific standards 4.9.4.V.1, 3, & 5-9, 4.9.4.C.3, and 4.9.13.O.
3. Additional information on the seating plan and other site features to determine full compliance with the use-specific standards.
4. Setbacks from both Fort Lowell and Country Club are 21 ft or the wall height, as measured from the back of future curb. Additional information on future curb location is needed to determine if setbacks to the north and east are being met.
5. Parking for this use would be required at a ratio of 1 space for every 100 sq ft of building area and outdoor seating area. If the entire “outdoor space” on the plan is intended to be used as outdoor seating, than the proposed parking is insufficient.
6. Pedestrian access (sidewalk/crosswalk) is required from each street. Pedestrian access is required throughout the development, including to the trash enclosure area.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
11/09/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed DTM offers the following comments:

Stamdar drequirements will apply

Close any unused driveways

Does not meet minimum driveway spacing from a signalized intersection according to transportation's access management guidelines Chapter 5.

5.1 mimimum distance of a driveway from a signalized intersection is 150 feet. Left turn in restrictions will apply. Driveways shall be designed with a median to restrict left turns in.

Zelin Canchola
11/10/2020 LOREN MAKUS ENGINEERING REVIEW Completed T22PRE0149
1. In FEMA flood hazard area. Elevation certificates will be required.
2. Maximum flood depth in parking areas is 2 feet.
3. Maximize water harvesting.
4. Close unused curb cuts.
5. Driveways must be provided with 25-foot radiuses.
11/12/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0149 - 3050 E FORT LOWELL RD - SiteGradingFloodplain 3050 E. Ft. Lowell

" Currently the parcel has a ¾" service line and a 1" service line serving the property. Should the existing water service lines and meter be too small to serve the proposed development, please contact New Services at TW_Common@tucsonaz.gov (or New Services desk at 520-791-5164) in the Tucson Water New Services Section to discuss options.

" Tucson Water has no adverse comments regarding this proposed development. Any questions, comments or concerns about these projects may be directed to:

Fabien Elenes, Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2202
Fabien.Elenes@tucsonaz.gov