Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: T20PRE0145
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T20PRE0145
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/26/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
11/02/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments
11/02/2020 GDAURIA1 COT NON-DSD FIRE Reqs Change * Fire sprinklers
* Fire access required within 150' of all exterior portions of building,
* Dead-end fire access roads exceeding 150' to be provided with an approved turnaround.
* Aerial access complying with 2018 IFC D105 to be provided.
* High-piled storage on first floor?
* Existing hydrant to be raised.
11/03/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. Not critical and not balanced. Detention not required if no adverse impact.
2. Five-year threshold retention required. From the property record cards, the mobile homes and the parking area on the east parcel should not be counted as existing conditions.
3. Maximize water harvesting.
4. Driveways should be constructed with 25-foot radiuses.
5. Six foot sidewalk required along Speedway frontage.
11/04/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0145 - 5925 E SPEEDWAY BL - Site Speedway Self-Storage

1. Water is currently being provided to this property via a ¾" water service line and a 5/8" water meter.
2. Should the existing water service line and meter be too small to serve the proposed development, please contact New Services at TW_Common@tucsonaz.gov (or New Services desk at 520-791-5164) in the Tucson Water New Services Section to discuss options.
3. Tucson Water has no adverse comments regarding this proposed development. Any questions, comments or concerns about these projects may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St., P.O. Box 27210
Tucson, AZ 85726-7210, (520) 837-2106
tim.rowe@tucsonaz.gov
11/04/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0145
Address: 5925, 5943 E Speedway Bl
Parcel(s): 121070160, 121070150
Zoning: C-2
Existing Use: Commercial – Animal Service
Proposed Use: Storage – Personal Storage

TRANSMITTAL DATE: November 4, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposed use of Personal Storage is permitted in the C-2 zone, subject to use-specific standards 4.9.10.C.3 & .6.
3. The proposed concept includes a building color palette and design that appears to not meet use-specific standards, as outlined below. Demonstrate compliance with development package submittal.
4.9.10.C.3. All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non-reflective material.
4.9.10.C.6. The facility’s exterior facade visible from adjoining residential properties or street frontage shall be earth tone in color and of masonry, stucco, or similar materials.
4. Development standards such as setbacks and building height appear to be met. Please note, setbacks to the north and south are based on wall height of the wall facing that property line, not building height. Wall height is measured from design grade to the top of the wall including parapet.
5. Parking for this use would be required at a ratio of 1 space for every 4,000 sq ft and 2 spaces for the office. As proposed, this use would require 28 spaces and 26 are provided. It appears the reductions proposed would be feasible.
6. Pedestrian access is required throughout the development. A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located.
7. A lot combination processed with Pima County will be required.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.