Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T20PRE0140
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/19/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 10/21/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard requirements will apply. |
| 10/21/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0140 Address: 7505 and 7507 E Broadway Bl Parcel(s): 13323110K Zoning: C-1 Existing Use: Vacant Proposed Use: Food Service TRANSMITTAL DATE: October 21, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposed use of Food Service is permitted in the C-1 zone, subject to use-specific standards 4.9.4.M.1 & 5 and 4.9.13.O. 3. It appears this site will function in tandem with the existing shopping center as parking spaces and circulation will be shared. If shared parking or off-site parking is planned, provide adequate documentation with DP submittal. 4. Broadway Bl is a Major Street and Route. Street setback is 21 ft or the wall height, whichever is greater, as measured from the back of future curb. 5. Bike parking is required. Two long-term and two short-term spaces are required. 6. The DP will need to include a reference sheet illustrating the entire site (including the existing shopping center) and an expansion calculation. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov. |
| 10/21/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | |
| 10/22/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 230 - 300 pm - T20PRE0140 - Site Black Rock Coffee - E. Broadway 1. Tucson Water has no adverse comments regarding this proposed development. 2. Any questions, comments or concerns about these projects may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 10/22/2020 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show complete pedestrian circulation 2. Show cross-access easements with adjacent developments 3. The project is within 500 feet of a landfill so the methane self-certification review is required Stephen Blood stephen.blood@tucsonaz.gov |