| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/12/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 10/19/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No sdvere comments. Standard requirments will apply |
| 10/20/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | T20PRE0137 1. This site is within a critical basin. Critical basin detention and 5-year threshold retention is required. A drainage report is required. 2. Maximize water harvesting. 3. Centralized solid waste collection is required. (ES must approve individual collection for multifamily projects. This approval will require a TSMR.) |
| 10/21/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * Fire sprinklers required. * No exterior portion of any structure to be more than 600' from a hydrant. * Fire lane signs required on one side of the roadway, * Fire access required to within 150' of any exterior portion of the units. * Fire access roads exceeding 150' shall be provided with an approved turn around. |
| 10/21/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0137 Address: 847 and 855 E Drexel Rd Parcel(s): 14019030A, 14019029A Zoning: R-2 Existing Use: Vacant Proposed Use: Multifamily Development TRANSMITTAL DATE: October 21, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposed use of Multifamily Development is permitted in the R-2 zone, subject to use-specific standards 4.9.7.B.6, .9, & .10. 3. Development standards such as density, height, and parking appear to be met. 4. Long-term bike parking is required at a ratio of 0.5 spaces per bedroom. With 84 bedrooms, a total of 42 spaces are required. Long-term bike parking can be provided within individual units, bike lockers or other means. See UDC Article 7.4.9.D. 5. Setbacks to the north, east and west are 10 ft or ¾ the wall height, whichever is greater. Setbacks need to be slightly larger as wall height is measured from design grade, not finished floor elevation. 6. Drexel Rd is a Major Street and Route. Setback on Drexel Rd is 21 ft or the wall height, whichever is greater, as measured from back of future curb. Drexel Rd appears to not be at full right-of-way width. Please verify future curb location with Department of Transportation and Mobility. 7. A lot combination processed with Pima County will be required. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov. |
| 10/22/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T20PRE0137 - SiteFlexible Lot Dev Colonia Mariposa, multi-family 1. There are no public water mains on this property, but a 6" PVC public water main (PN 135-1985 & FR 11739) terminates near the proposed cul-de-sac at the NW corner of the project. 2. New on-site public water mains will need to connect PN 135-1985 & FR 11739 to the 8" cement asbestos public water main (PN 061-1964) on the south side of Drexel Road. 3. The design of the new on-site public water mains will need to go through Tucson Water's Master Plan and Design Plan review processes, and the new on-site public water mains will need to be located in either public streets or public water line easements that are a minimum of 15' wide. 4. Any questions, comments or concerns about these projects may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |