Plan Number: T20PRE0135
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0135
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/07/2020 SBLOOD1 ENGINEERING REVIEW Completed 1. Make sure the drainage channel through Fairway Groves is cleaned out and maintained.

2. Threshold retention, based on density, will be required.

Stephen Blood
stephen.blood@tucsonaz.gov
10/07/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
10/08/2020 GDAURIA1 COT NON-DSD FIRE Reqs Change * Where the number of dwelling units exceeds 30 units (lots 20 - 67) shall be provided with two separate and approved fire access roads (D107).
* Hydrants required so that the distance to any exterior portion of a structure does not exceed 400' (600' if sprinklered).
10/12/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change There is a concern with lots facing Linderbrooke road. Further discussion is required to mitigate backing out into the road.

A updated traffic impact analysis is required.

Zelin Canchola
10/14/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0135
Address: 8701 E Stone Meadow Cl
Parcel(s): 136-30-1380
Zoning: R-1
Existing Use: Vacant
Proposed Use: Residential – Flexible lot development

TRANSMITTAL DATE: October 14, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a Flexible Lot Development, which is permitted in the R-1 zone subject to use-specific standards 8.7.3.
3. Density standards appear to be met. Additional information is needed to determine conformance with the other FLD development standards.
4. Note, an Architectural Variation Plan and Privacy Mitigation Plan (for multistory residences) will be required.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov.
10/15/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T20PRE0135 - Tentative Plat Bella Tierra 2

1. The necessary public water line extensions for this project will need to go through Tucson Water's Master Plan and Design Plan review processes.
2. During the master water planning of this project, please plan on looping the on-site water mains to two different points in Tucson Water's existing water distribution system as required by Section 8-06.4.2.A of Tucson Water's Design Manual to meet water quality and fire flow requirements, or explaining what legal and/or technical reasons prevent such looping.
3. Any questions, comments or concerns about these projects may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
Tim.Rowe@tucsonaz.gov