Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION
Plan Number - T20PRE0128
Review Name: PREAPPLICATION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/29/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 09/30/2020 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show solid waste collection vehicle maneuverability 2. Show pedestrian connection to Country Club RD 3. Maximize water harvesting 4. Meet minimum PAAL width (24’) requirements Stephen Blood stephen.blood@tucsonaz.gov |
| 10/01/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard requirements will apply. |
| 10/01/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 230 - 300 pm - T20PRE0128 - 3540 N Cntry Club Rd - Site Country Club & Greenlee Housing " 3540, 3532, 3524 Country Club Rd each have a 3/4" service connection. " To further discuss options for obtaining water service further, please contact Mr. Ray Munoz or Mr. Jeremiah Jenkins at 837-2207 in the Tucson Water New Services Section to discuss: - Potential points of connection for the waterline extension to Tucson Water's existing water distribution system. - The number of water service lines, water meters, and meter sizes, necessary to serve this development. - The advantages and disadvantages of installing the necessary water meters via Tucson Water's Job Order Contract (JOC) process. - Please note that if hydraulic modeling is necessary to verify which potential points of connection have the capacity necessary to serve the proposed development, it can be done as part of Tucson Water's Job Order Contract (JOC) process. All questions, comments or concerns about these comments may be addressed to: Fabien Elenes, Engineering Associate Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2202 Fabien.Elenes@tucsonaz.gov |
| 10/01/2020 | MROSS2 | COT NON-DSD | FIRE | Completed | Fire apparatus access to within 200 feet of all portions of the buildings Multi family housing are required to have automatic fire sprinklers |
| 10/01/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0128 Address: 3540, 3532, 3524 N Country Club Rd Parcel(s): 11103064C, 11103064D, 11103064E Zoning: C-1 Existing Use: Vacant Proposed Use: Residential - Multifamily Development TRANSMITTAL DATE: October 1, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposed use of Multifamily Development is permitted in the C-1 zone. 3. Development standards such as density, setbacks, and height appear to be met. 4. Parking is required at 1.5 spaces per unit. The proposed parking is not adequate. There is the option of an administrative review for reduced parking called an Individual Parking Plan (IPP). Additional information can be found online: https://www.tucsonaz.gov/files/pdsd/IPP_application_1.pdf 5. Additional information is needed to determine whether parking maneuverability meets standards. 6. Bike parking is required as follows: Short-term 0.10 spaces per bedroom. Minimum requirement is 2 spaces. Long-term 0.5 spaces per bedroom. Minimum requirement is 2 spaces. 7. Pedestrian access from the street is required. 8. Please note, the required street setback is 21 ft or 1.5 times the wall height. 9. A lot combination is required to be submitted and approved by Pima County. 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |