Plan Number: T20PRE0127
Parcel: Unknown

Address:
8015 S RITA RD

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0127
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/24/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Ensure that Zoning and Engineering comments are addressed
09/29/2020 GDAURIA1 COT NON-DSD TRAFFIC Completed No Adverse comments. Standard requirements will apply.

Zelin Canchola
Transportation and Mobility Engineering
09/30/2020 SBLOOD1 ENGINEERING REVIEW Completed 1. Balanced basin detention required: no increase for peak discharge for 2, 10, and 100-yr events.

2. 5-yr threshold retention is required.

3. Maximize water harvesting

4. Show trash enclosures with access and provide waste stream calculations per tech standard 8-01

5. Address the existing channel in the drainage design. Show no adverse impact to dominos drainage.

6. Davis Monthan Air Force Base (DM AFB) approach and departure zone 2 (ADC-2) requirements apply.

Stephen Blood
stephen.blood@tucsonaz.gov
10/01/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T20PRE0127 - 8934 E DINA MARIE PL - Site Rita Rd. Readiness Center

" Currently there is 12" PVC water main to the north on Dina Marie Place with 6" stubs along the south of the water main. There is also a 16" CA water main along Rita Road.

" The design of the on-site water mains will need to go through Tucson Water's Master Water Plan process, and Design Plan process.

" During the design of the on-site water mains, please plan on all of the following:
- Locating the on-site water mains in the private streets, which will need to be dedicated as public utility easements by the final plat.
- Looping the on-site water mains to the maximum extent practicable, and
- Connecting on-site water mains to multiple points in Tucson Water's existing water distribution system.

Any questions, comments or concerns about these comments may be addressed to:
Fabien Elenes, Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2202
Fabien.Elenes@tucsonaz.gov
10/01/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0127
Address: 8934 E Dina Marie Pl and numerous others
Parcel(s): 141138350 and numerous others
Zoning: I-1
Existing Use: Vacant
Proposed Use: N/A

TRANSMITTAL DATE: October 1, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. As this site is owned and managed by the State of Arizona, development is exempt from local zoning regulations. Development must still comply with local floodplain and other ordinances. Development package submittal is required.
3. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
10/05/2020 SBEASLE1 COT NON-DSD FIRE Needs Review