Plan Number: T20PRE0124
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0124
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Ensure that Zoning, Engineering and any other division comments are addressed.
09/28/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed None
09/29/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0124
Address: 7804 S Park Av
Parcel(s): 140-43-013E
Zoning: Pima County
Existing Use: N/A
Proposed Use: N/A

TRANSMITTAL DATE: September 29, 2020

COMMENTS:
1. This site is located in unincorporated Pima County. City of Tucson zoning regulations do not apply.
2. The comments provided are preliminary and are not to be assumed as a complete review of the proposal..

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
09/29/2020 GDAURIA1 COT NON-DSD FIRE Completed
09/29/2020 SBLOOD1 ENGINEERING REVIEW Completed 1. Provide development package that conforms with Admin Manual 2-06

2. Provide concurrence with TAA hydrologist for conformity with TIA master drainage report

Stephen Blood
stephen.blood@tucsonaz.gov
10/01/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0124 - 7804 S PARK AV - Minor SubdivPDMR - Membrane Structure Hangar

" Currently there is 12" PVC and DIP waterline going directly through the middle of the proposed project. Near the southwest side of the proposed building we have a 6" Fire Hydrant. Within the proposed hangar there is also an existing 3" Fire Service line and two 2" service connections in that area.

" 12" waterline will need to be relocated in order to keep the demand needed for the other Fire Hydrants and Fire Services in the area. During the design of the on-site water mains, please plan on all the following:
- Locating the on-site water mains in the private streets, which will need to be dedicated as public utility easements by the final plat.
- Looping the on-site water mains to the maximum extent practicable, and
- Connecting on-site water mains to multiple points in Tucson Water's existing water distribution system.

Any questions, comments or concerns about these comments may be addressed to:
Fabien Elenes, Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2202
Fabien.Elenes@tucsonaz.gov