Plan Number: T20PRE0117
Parcel: Unknown

Address:
4350 N WEGNER LN

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0117
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/14/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed 5.4. MAJOR STREET AND ROUTES SETBACK ZONE (MS&R)

5.4.2. APPLICABILITY

The MS&R standards apply to the following uses on property, any portion of which abuts or is adjacent to a street designated on the City’s or County’s MS&R Plan:

A. New structures;

B. Changes of use, including new structures occurring on vacant land;

C. Uses of land or structures legally existing as of June 27, 1988, that are expanded in floor area, lot coverage, parking, seating capacity, or any other expansion of use, as listed below. Exception. An expansion of off-street parking for a nonconforming existing use that increases the number of spaces to the minimum required by the UDC for that use is exempt from counting toward the 25% expansion: (See Figure 5.4-A.)

1. If the expansion is less than 25%, the MS&R applies to the proposed expansion. The remainder of the use or structure shall be governed by provisions in force at the time of initial approval for the use or structure;

2. If the expansion is 25% or more, the MS&R applies to the proposed expansion and to the parking and landscaping standards that apply to the overall development; or,

3. Expansions that occur after the effective date of the MS&R shall be cumulated in determining the 25% expansion.

If applicable: Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
09/16/2020 GDAURIA1 COT NON-DSD FIRE Completed * Option 1 without firewall, may require fire sprinklers throughout both new and existing structures depending on occupancy type,
09/17/2020 LOREN MAKUS ENGINEERING REVIEW Completed Option 1
1. Not floodplain, not critical and not balanced.
2. Show site meets retention requirements.
3. Maximize water harvesting.
Option 2
1. Development package.
2. Maximize water harvesting.
09/21/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirments will apply.
09/24/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0117 - 4351 N FAIRVIEW AV - Site The Specialist

Tucson Water does not serve this property. If you have any questions for the water utility, please contact the water company that serves this property.

Fabien Elenes, Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210, Tucson, AZ 85726-7210
(520) 837-2202, Fabien.Elenes@tucsonaz.gov
09/24/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner
PROJECT: Thursday Pre-submittal meeting – T20PRE0117
Address: 4351 N Fairview Av, 4350 N Wegner Ln
Parcel(s): 10411001M, 104114340
Zoning: MU
Existing Use: Automotive Service and Repair, Minor and/or Parking
Proposed Use: (same)

TRANSMITTAL DATE: September 24, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposed use is Automotive Service and Repair, Minor, which is permitted in the MU through a Zoning Examiner Special Exception procedure and is subject to use-specific standards 4.9.5.C.6. The proposed secondary use is Parking, which is also permitted in the MU zone through a Zoning Examiner Special Exception procedure and is subject to use-specific standards 4.9.5.C.6.
3. As the two sites are separated by a right-of-way, they cannot be considered a single site. Development on each site will require its own development package. Whichever site is used for building would likely require the other site to be used for parking. This would require an offsite parking agreement. See UDC Article 7.4.6.B.1.
4. If the proposed building is constructed on the Fairview site, it appears to be more than a 25% expansion. As such, full code compliance will be triggered for the entire site, including landscaping, pedestrian access, trash enclosure, etc.
5. If the proposed building is constructed on the Wegner site, the major constraints will be the street setback, landscaping, and trash requirements, assuming the parking will be handled on the Fairview site.
6. Parking will be calculated at a ratio of 1 space per 300 sq. ft. More information is needed to provide an accurate calculation.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.