| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/08/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 09/08/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * Hydarants must be located within 400' of any exterior portion of any building. |
| 09/14/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard requirments will apply. |
| 09/16/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Site is in neither balanced nor critical basin. 2. Alternate sidewalk location requires TSMR. 3. Five-year threshold retention required. 4. Show driveway/garage locations to demonstrate space remains on street for parking spaces. |
| 09/16/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T20PRE0114 - 2451 S CAMPBELL AV - SiteGrading FLD Campbell Ave & 36th St 1. TucsonWater has an existing 6" cement asbestos water main (PN FN271A) in Campbell Avenue, an existing 6" cement asbestos water main (PN FN271A) in34th St., and an existing 4" cement asbestos water main (PN FN271A) in Kramer Avenue that can serve this project. 2. The design of the on-site water mains will need to go through Tucson Water's Master Water Plan process, and Design Plan process. 3. During the design of the on-site water mains, please plan on all of the following: a. Locating the on-site water mains in the private streets, which will need to be dedicated as public utility easements by the final plat. b. Looping the on-site water mains to the maximum extent practicable, and c. Connecting on-site water mains to multiple points in Tucson Water's existing water distribution system. 4. Any questions, comments or concerns about these comments may be addressed to: Tim Rowe, Sr. Engineering Associate Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 09/17/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0114 Address: 2451 S Campbell Av Parcel(s): 13005303H Zoning: C-1; R-2 Existing Use: Residential Proposed Use: Residential; FLD TRANSMITTAL DATE: 9/17/2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for development of a Flexible Lot Development (FLD), which is a permitted use subject to use-specific standards 8.7.3. 3. Development standards such as density, functional open space and setbacks appear to be met. 4. Visitor Parking is calculated correctly, but it is unclear how the on-street parking will function with the garages. Please clarify the size of all parking spaces and that sufficient access and maneuverability is provided. 5. Ensure that there is continuous pedestrian circulation throughout the site (7-01.3.0 Technical Standards). The southwest units appear to have sidewalk access, but said access needs to continue to Campbell Ave. 6. Please note, per UDC Article 8.7.3.M.1.B.1, submittal of an Architectural Variation Plan (AVP) will be required. The AVP is triggered due to the proposal exceeding 20 single-family residences. 7. Please note, per UDC Article 8.7.3.M.2.A, a Privacy Mitigation Plan (PMP) will be required. The PMP is triggered due to the adjacency to existing residential development. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |