| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. Indicate graphically, where possible, compliance with conditions of PAD-12 document. |
| 09/03/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * Hydrants |
| 09/08/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Balanced basin detention and 5-year threshold retention required. 2. Follow PAD requirements. 3. Connection to Drexel Road and development of north area should be expected. |
| 09/08/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | Standard requirements will apply. |
| 09/09/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T20PRE0112 - no street address yet - Tentative PlatFLD Valencia Crossing 1. A Master Water Plan will be required by Tucson Water for this project. 2. During the master water planning of this project, please plan on looping the on-site water mains to two different points in Tucson Water's existing water distribution system as required by Section 8-06.4.2.A of Tucson Water's Design Manual, or explaining what legal and/or technical reasons prevent such looping. 3. Any questions or concerns about these comments may be addressed to: Tim Rowe, Sr. Engineering Associate Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 09/09/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0112 Address: No address Parcel(s): 140-36-005F Zoning: PAD-21 Existing Use: Vacant Proposed Use: Flexible Lot Development TRANSMITTAL DATE: September 9, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The subject property is located in Valencia Crossings (PAD-21), Area B. This area permits all uses which are permitted in the City’s C-2 and I-1 zones. Single-family residential and flexible lot development (FLD) uses are both permitted in the C-2 zone. 3. In the PAD, Table III.C. Development Standards includes the required lot size, height, setbacks, etc. The development standards appear to permit the proposed lot configuration, without the use of the FLD option. 4. A detailed review of the proposal, whether a single-family residential subdivision or flexible lot development, will occur with development package submittal. 5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |