Plan Number: T20PRE0111
Parcel: Unknown

Address:
3550 E CORONA RD

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0111
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/01/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
09/03/2020 GDAURIA1 COT NON-DSD FIRE Reqs Change * Fire Department Access Doors 3206.7.5 (man doors)
The required fire department access doors shall be distributed such that the lineal distance between adjacent fire department access doors does not exceed 125 feet measured center to center; if high piled storage.

* Required Aerial Access D105.1
Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet (9144 mm), approved aerial fire apparatus access roads shall be provided.
Aerial fire apparatus access roads shall have a minimum unobstructed width of 26 feet
One or more of the required access routes meeting this condition shall be located not less than 15 feet (4572 mm) and not greater than 30 feet (9144 mm) from the building, and shall be positioned parallel to one entire side of the building.

* Required Two Means of Fire Access D104.1
Buildings or facilities exceeding 30 feet (9144 mm) or three stories in height shall have not fewer than two means of fire apparatus access for each structure.
Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses.

* Several Hydrant requried
09/03/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is within a balanced basin. Retention and balanced basin detention is required.
2. The wash through the site is over 100 cfs based on TSMS nodes. Floodplain delineation and riparian resource inventory and preservation is required.
3. A Floodplain Use Permit will be required.
4. Water harvesting must be maximized.
5. Provide for solid waste and recycling collection.
09/08/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Standard requirements will apply.

Sidewalk/curb required along Corona and Los Reales. A muliti use path is acceptable along Alvernon.

A traffic impact analysis (TIA) is required.
09/09/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 130 - 200 pm - T20PRE0111 - 3550 E CORONA RD - Site Sonoran Business Pk, 270,000 sf bldg.

1. There is an existing 16" water main in Corona Road on the north side of the property, and an existing 24" water main in S. Alvernon Way on the east side of this property. This project may connect to the 16" water main in Corona Road.

2. Plan on any necessary on-site fire loop connecting to both the existing 16" water main in Corona Road and the existing 24" water main in S. Alvernon Way.

3. Any necessary on-site fire loop will need to be centered within a new water line easement that is a minimum of 15' wide.

4. There are also several existing water line easements on the property for water lines that were never built, that may need to be released.

5. Any questions or concerns about these comments may be addressed to:

Tim Rowe, Sr. Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
09/09/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0111
Address: 3550 E Corona Rd
Parcel(s): 14041133A
Zoning: I-1
Existing Use: Vacant
Proposed Use: Storage – Commercial Storage

TRANSMITTAL DATE: September 9, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The propose use of Commercial Storage is permitted in the I-1 zone, subject to use-specific standards 4.9.10.A and 4.9.13.Q.
3. Development standards such as parking, setbacks and building height appear to be met.
4. Pedestrian access (sidewalk/crosswalk) is required from each street. Pedestrian access is also required throughout the development. Exceptions can be found in TSM Section 7-01.3.3.B.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.