Plan Number: T20PRE0108
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0108
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/14/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Vehicular Use Area

The standards in this Section 7.6.4.B apply to all sites that provide more than four parking spaces.
08/18/2020 GDAURIA1 COT NON-DSD FIRE Completed * The residence >3600 square feet under roof requires fire sprinklers.
08/24/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No applicable comments from Transportation and Mobility
08/26/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is within 500-year floodplain. No special conditions unless a critical facility is proposed. Critical facilities include day care and adult care homes.
08/26/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T20PRE0108 - 4310 N MAINARD DR - Site New residence with guest house

1. Tucson Water has no public water mains fronting this property. How is water currently being delivered to the existing house?
2. Until the question posed above is answered, Tucson Water can offer no further comments on this proposed development.
3. Any questions or concerns about these comments should be addressed to:

Tim Rowe, Sr. Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
08/26/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed September 9, 2020

Tucson Water has no opposition to the proposed new residence wtih new guest house.

Please check with the owner(s) of the groundwater well that will serve this property, to determine if they have any water mains or water-line easements on the property that need to be protected, or have any opposition to the proposed new residence w new guest house.

If you have any further questions about this matter please do not hesitate to contact me at the number shown below my signature.

Tim Rowe, Sr. Engineering Associate
Tucson Water, New Development Section
310 W. Alameda St.
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
08/27/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0108
Address: 4310 N Mainard Dr
Parcel(s): 108-21-009E
Zoning: MH-1 (R)
Existing Use: Single-Family Residential
Proposed Use: Single-Family Residential

TRANSMITTAL DATE: 8/27/20

COMMENTS:
1. If development of 3 units is proposed, development must comply with the Administrative Manual Section 2-06 - Development Package. If 2 units are proposed, development must comply with residential development standards.
2. The proposal is to expand development on the site by adding a single-family residence (or two) to the site. It is unclear if the proposal is for a total of 2 or 3 residences.
3. The MH-1 zone would require a lot size of 10,890 sq ft for two dwelling units and a lot size of 16,355 sq ft for three dwelling units. This lot would allow up to 3 units. However, if 3 units are proposed, commercial development standards would be required such as parking, landscaping, pedestrian access etc.
4. Regarding the proposed development of the site, please note the following:
a. The street setback is required at a minimum of 20 ft or 1.5 times the wall height.
b. The “kitchenette” on the first floor of the western house would be considered a full kitchen and thus 2 dwelling units would be proposed in the building. To be considered not a full kitchen, it can only include a single-bowl sink, under-the-counter fridge, microwave, etc. A full-size fridge and stove are not permitted.
c. As floor plans for the existing house and proposed guest house have not been provided, it is not possible to determine if this is 1 or 2 dwelling units. Additional details are needed.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.