Plan Number: T20PRE0100
Parcel: Unknown

Review Status: Active

Review Details: PREAPPLICATION

Plan Number - T20PRE0100
Review Name: PREAPPLICATION
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
07/31/2020 ANY TUCSON WATER NEW AREA DEVELOPMENT REVIEW Active
08/03/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed 7.6.4. LANDSCAPE STANDARDS

Vehicular Use Areas

The standards in this Section 7.6.4.B apply to all developments that provide more than four motor vehicle parking spaces.

Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirement
08/07/2020 GDAURIA1 COT NON-DSD FIRE Completed * Fire spinklers required (if built under the IBC).
* Fire access (20") fron Sycamore, required to within 150' of all partions of buildings' exterior.
* If patios are enclosed, a gate to the public way must be provided.
08/12/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is impacted by floodplain. Floodplain compliance will be required.
2. Minimum access aisle width is 20 feet. Minimum width for a PAAL is 24 feet.
3. Show how solid waste storage and collection locations will meet Technical Standard 8-01.
08/17/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments.Standard requirements will apply.
08/19/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0100
Address: 1513 N Sycamore Bl
Parcel(s): 122131970
Zoning: R-2
Existing Use: Vacant
Proposed Use: Multifamily Development

TRANSMITTAL DATE: August 19, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is to develop a vacant lot into multifamily development, which is a permitted use in the R-2 zone subject to use-specific standards 4.9.7.B.6, .9, & .10.
3. The size of this lot (15,000 sq ft) would permit a maximum of 5 dwelling units based on the allowed density in the R-2 zone.
4. The proposed floor plans indicate a total of 3 bedrooms in each unit. Each 3-bedroom unit would require 2.25 parking spaces. If 2-bedroom units are proposed, each unit would require 2 parking spaces. The total number of proposed parking spaces in the provided concept plans do not meet standards. Parking maneuverability (driveway, etc.) also appears to not meet standards. Accessible parking is also required. Parking may be potentially modified through an application for an Individual Parking Plan.
5. When more than 2 units are proposed on a site, the development is considered nonresidential for the purpose of determining required setbacks. As such, the required setbacks to the north, west and south are the greater of 10 ft or ¾ the proposed wall height. The proposal does not appear to meet setback standards, although dimensions were not provided. Setbacks may be potentially modified through an application for a Design Development Option.
6. Pedestrian access from the street and throughout the development site is required.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.