Plan Number: T20PRE0098
Parcel: Unknown

Address:
2850 E RIVER RD

Review Status: Active

Review Details: PREAPPLICATION

Plan Number - T20PRE0098
Review Name: PREAPPLICATION
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/07/2020 GDAURIA1 FIRE REVIEW Completed * Any structure greater tha 30' in height will require 26' fire aeriael access. All other fire access shall be min. 20' width.
* New hydrant locations to be approved by TFD.
* If built using the IBC; all residential units to be sprinklered
* Gates and controls to be approved by TFD.
* Fire lane signage at residential entry will be required.
* Verify fire access to within 150' of any portion of any structure.
* If any residential unit have sleeping room emergency egress to the rear; access to the public way to be provided.
08/10/2020 LOREN MAKUS ENGINEERING REVIEW Completed This site is on the north bank of the Rillito. It is outside of mapped floodplain areas.
The Engineering Section of PDSD will not request addtional conditions.
Please note that 5-year threshold retention is required for this development.
08/25/2020 ANY URBAN PLANNING REVIEW Active
08/26/2020 ZELIN CANCHOLA COMMENTS COMMENTS Completed No adverse comments. Standard requirememts will apply during development process.

A traffic impact analysis is required.
08/26/2020 ELISA HAMBLIN ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Elisa Hamblin, AICP; Principal Planner
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T20PRE0098
Address: 2850, 2950, 2980 and 3030 E. River Road
Parcel(s): 108-24-004A, 108-24-026J, 108-24-026K & 108-24-003E
Existing Zoning: SR (COT), CR-1 (PC), SR (PC)
Proposed Zoning: PAD
Existing Use: Single family residential
Proposed Use: Various, residential, commercial, retail

TRANSMITTAL DATE: August 26, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for a rezoning to a PAD. As such, development standards outlined in the PAD will be used to review the proposed development at time of development package submittal.
3. Please note, the regulations of existing overlays (such as SCZ and MS&R) will still apply unless expressly modified through the PAD.
4. Landscape requirements can be discussed further with Andy Connor at andrew.connor@tucsonaz.gov or 520-837-4950.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.