Review Date Reviewer's Name Type of Review Description Status Comments
07/15/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. Show MS&R ROW for both Craycroft and Speedway. The future width is 120 feet. Also show intersection widening per the MS&R plan.
2. Curb returns (25-foot radii) required for driveways.
3. Show roof drainage. Roof drainage cannot be discharged over sidewalks.
4. Maximize water harvesting.
07/15/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
Note: A 30' landscape buffer is not necessary.
07/16/2020 GDAURIA1 COT NON-DSD FIRE Completed
07/21/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Standard requirements will apply. New driveways required. Driveway on Craycroft to be constructed as right in right out due to proximity of southbound left turn lane.
07/23/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0083
Address: 5501 E Speedway Bl
Parcel(s): 12106017C
Zoning: C-2
Existing Use: Retail – General Merchandise Sales
Proposed Use: Retail – Food and Beverage Sales

TRANSMITTAL DATE: July 23, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is for the complete removal of an existing retail use. The new building will be considered a food and beverage sales use. This is permitted in the C-2 zone.
3. Development standards such as height, setbacks and parking appear to be met with this proposal.
4. The drive aisle at the northwest portion of the site is required to be 24 ft in width, unless a Parking Design Modification Request (PDMR) is approved.
5. Pedestrian access (sidewalk/crosswalk) is required from each street that the project has frontage.
6. Access is illustrated from an adjacent parcel. Provide documentation of cross access agreement with development package submittal.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
07/23/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T20PRE0083 - 5501 E SPEEDWAY BL - Site Salad and Go, new restaurant
1. The existing building on the site obtains its water via a 1" service line and 1" water meter.

2. If there is any question about whether this service line and meter are large enough for the proposed new restaurant, please contact Ray Munoz at 837-2207 in the Tucson Water New Services Section.

Fabien A. Elenes, Engineering Associate
520-837-2202, Tucson Water