Plan Number: T20PRE0076
Parcel: Unknown

Review Status: Completed

Review Details: PRESUB MTG

Plan Number - T20PRE0076
Review Name: PRESUB MTG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/01/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. No development of any kind (clearing, grading, fences, walls or driveways for example) within the gas line easement without the specific written permission El Paso Natural Gas/Kinder Morgan.
2. Balanced basin detention and 5-year threshold retention is required.
3. Water harvesting must be maximized.
07/06/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed No adverse comments. Standard requirements will apply.

Zelin Canchola
Transportation and Mobiity Engineering
07/06/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
07/06/2020 GDAURIA1 COT NON-DSD FIRE Reqs Change * Hydrant required at SW corner of property.
* Show driveway and access concept.
07/08/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0076
Address: 9497 E Old Vail Rd
Parcel(s): 14118547A
Zoning: I-1
Existing Use: Vacant
Proposed Use: Commercial - Animal Service

TRANSMITTAL DATE: July 8, 2020

COMMENTS:
1. Clarification is needed on which parcel is under consideration for development. The documents submitted for the pre-submittal meeting reference both lot 30 and lot 31 as the subject parcel. Additional comments may apply.
2. Development must comply with the Administrative Manual Section 2-06 - Development Package.
3. The proposal is for development of a new Animal Service use on a vacant parcel. This is permitted in the I-1 zone. The site is also within the Davis-Monthan Air Force Base overlay, subject to the following standards which may impact development:
a. The maximum FAR is .20 of the project site area.
b. The maximum permitted building height is 62 feet from design grade elevation or the height limit of underlying zone, whichever is more restrictive.
4. The site is subject to 0 ft setbacks to the north, east and west. The street setback is 21 ft or the wall height, as measured from the back of future curb.
5. Parking will be required at a ratio of 1 space per 400 square feet of building area.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
07/08/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed T20PRE0076 - 9497 E OLD VAIL RD - SiteGradingSWPPP Reata Veterinary Hospital

An existing 1-inch water service line extends from the 16-inch water main in Old Vail Road to this property, but I have not been able to find any record of an existing water meter on the property

Should the local fire authority require the installation of a fire hydrant, there is an existing 8-inch water line stub that extends from the 16-inch water main in Old Vail Road to the SW corner of this property that can be utilized for this purpose.

After a water fixture unit count has been conducted for the project using the 2018 International Plumbing Code, and the fire flow requirements have been established by the local fire authority, please contact Ray Munoz at 837-2207 in the Tucson Water New Services Section to discuss:

The number of water service lines, water meters, and meter sizes, necessary to serve this development.

The advantages and disadvantages of installing the necessary water service lines and meters via Tucson Water’s Job Order Contract (JOC) process.

The advantages and disadvantages of installing any necessary fire hydrants via Tucson Water’s Job Order Contract (JOC) process.

Tim Rowe, Sr. Engineering Associate
Tucson Water, New Development Section