| 06/16/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Engineering has no comment. |
| 06/16/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | |
| 06/17/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | No adverse comments. Standard requirements will apply. |
| 06/18/2020 | EHAMBLI1 | LANDSCAPE | REVIEW | Passed | Landscape review unavailable. Please contact Zoning Review staff for specific questions. |
| 06/18/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0075 Address: 3955 E Broadway Bl Parcel(s): 126070780 Zoning: C-1 Existing Use: Retail Proposed Use: Commercial – Food Service TRANSMITTAL DATE: June 18, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. It appears a development package has already been approved for this site, but this proposal would significantly change the layout and use of the site. Please resubmit the development package for complete re-review. 3. The proposed use of Food Service is permitted in the C-1 zone, subject to use-specific standards 4.9.4.M.1 & 5 and 4.9.13.O. 4. Required parking for this use would be 10 spaces, which appears to be met on site. 5. Setbacks and other development standards appear to be met. 6. Verify landscaping requirements for landscape buffer along Longfellow. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |
| 06/19/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | T20PRE0075 - 3955 E BROADWAY BL - Site NWC Broadway Longfellow Restaurant 1. This property is currently served by a ¾ inch water service line connected to the 6 inch water main in Longfellow. 2. I was unable to find any information about what size water meter may be on the property 3. If the existing water service line and/or meter are insufficient for the proposed use of this property, please contact Ray Munoz at 837-2207 in the Tucson Water New Services Section to discuss: -What size water service lines and water meters are necessary to serve this development. -The advantages and disadvantages of installing the necessary water service lines and/or meters via Tucson Water's Job Order Contract (JOC) process. Tim Rowe, Sr. Engineering Associate Tucson Water, New Development Section 310 W. Alameda St. P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 |