| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Show pedestrian route to solid waste container that doesn't cross window stacking. |
| 05/19/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * Deferred submittal to TFD for hood system. |
| 05/19/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | No additional landscape will be required. |
| 05/20/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0064 Address: 1903 E Speedway Bl Parcel(s): 123-07-292C, 123-07-291B Zoning: C-1 Existing Use: Commercial – Food Service Proposed Use: Commercial – Food Service TRANSMITTAL DATE: May 20, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for a change to an existing food service use. It appears a portion of the existing building will be demolished to add in a drive-through lane. A new curb cut onto Speedway Bl is also requested. 3. The change to the building changes the size to 2,200 sq ft. A 200 sq ft patio is also proposed. This would require a total of 24 parking spaces. Only 18 spaces have been provided on site. 4. A Parking Design Modification Request (PDMR) can be requested to reduce up to 10% of the required parking spaces. Only 2 spaces could be reduced with the PDMR. The Design Review Board (DRB) reviews the PDMR and provides the PDSD Director with a recommendation. Additional vehicle parking spaces can be reduced by providing extra bike parking spaces at a ratio of 6 extra bike parking spaces for 1 vehicle parking space. Please note, per 7.4.5.E.1.b. the cumulative reduction cannot exceed 20% of the required parking, which would total 4 parking spaces in this case. 5. Other options to reduce required parking would be to obtain an off-site parking agreement with an nearby use, or pursue a variance with the Board of Adjustment. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |
| 05/26/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | * Deferred submittal to TFD for hood system. |
| 05/26/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | May 26, 2020 T20PRE0064 Zelin Canchola Transportation and Mobility Engineering No adverse comments. Standard requirements will apply. |
| 05/28/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 1:30 - 2:00 pm - T20PRE0064 - 1903 E SPEEDWAY BL - Site: Chipotle Mexican Grill This site is currently served by two existing water meters, as described below: A 2” water meter connected to the 12” water main in Speedway Blvd via a 2” water service line. A 5/8” water meter connected to the 12” water main in Speedway Blvd via a 2” water service line. If these existing water meters cannot supply the water needed by the project, please contact Ray Munoz at 837-2207 in the Tucson Water New Services Section to discuss: Potential points of connection to Tucson Water’s existing water distribution system. Please note that hydraulic modeling may need to be performed to verify which potential points of connection have the capacity necessary to serve the proposed development. The number of water service lines, water meters, and meter sizes, necessary to serve this development. The advantages and disadvantages of installing the necessary water meters via Tucson Water’s Job Order Contract (JOC) process. Tim Rowe Tim.Rowe@tucsonAz.gov |